DS1 Expansion Panels Will Efficiently Modernize Critical Legacy Timing
Syncworks recently released two new network timing DS1 Expansion Panels for their telecom, cable, and utilities customers. The panels were developed to increase the DS1 or Composite Clock output capacity of an existing BITS by 20 additional ports. “These panels were designed as a way to economically meet the timing needs of mid- to larger-sized Central Offices. Whether we’re completely replacing an existing legacy BITS clock or simply increasing its current output capacity, these panels can be easily deployed to address either scenario.” says Syncworks Technical Director Rob Jodrie. “This solution is a key component of what Syncworks refers to as the 3rd Generation BITS. While the need for the distribution of frequency timing, DS1 and CC, is typically not expanding, legacy systems that support critical services such as 911 and SS7 are still dependent on these reference signals. These network elements are likely to remain operational for the foreseeable future. When deployed in conjunction with the Microchip TimeProvider® 4100, new service requirements for 5G and R-PHY can be met while servicing existing timing requirements.
While the new DS1 expansion panels were designed with the Microchip TimeProvider® 4100 series in mind. The DS1 and Composite Clock panels will also expand capabilities for the Oscilloquartz 540, the Meinberg Grandmaster clocks and legacy Telecom Solutions, TSG-3800, and other BITS. These panels have A and B power inputs and dual input references for redundancy. Loss of power, input, and port alarms also report via both LED and discreet alarms. Connectivity to network elements is achieved via the wire wrap connections on the back of the panels.
Overview of the DS1 Input/Output Panel
The Syncworks T1 I/O DS1 Expansion Panel is designed to specifically meet our customer’s need to continue supporting legacy synchronization needs in today’s small and large offices, by expanding the number of T1 outputs provided by T1 clock/sync sources, e.g. the Microchip TimeProvider® 4100 (TP4100).
The Syncworks’ T1 I/O Expansion Panels unique T1 clock input design interfaces with dual and independent T1 outputs from the T1 clock sources to expand the system’s total number of available T1 outputs to include the 20 T1 outputs; 10 of the T1 outputs replicate the T1 signal on the Primary Input and 10 of the T1 outputs replicate the T1 signal on the Secondary Input.
The panel has redundant power connections, Power A and Power B, to accept -48VDC from the office battery system. The panel has dual T1 Inputs, the Primary Input and the Secondary Input, that
are connected to a Timing Signal Generator, e.g. TP4100 T1 outputs; the two inputs can have the same framing type, Super Frame (SF), Extended Super Frame (ESF), and ESF with Sync Status
Messaging (SSM) or different framing types. Once both T1 inputs are connected, the panel provides 20 T1 Outputs, 10 associated with the Primary Input and 10 associated with the Secondary Input.
The panel provides alarm indicators/LEDs for each power input, each T1 input, and the 20 T1 outputs; if any alarm condition is detected the Alarm LED and Alarm Relay will be activated for
remote monitoring of the panel, the alarm will remain active until the source of the alarm condition is resolved.
The Syncworks T1 I/O DS1 Expansion Panel comes with reversible rack ears that allow it to be mounted in either 19″ or 23″ equipment racks and the panel height will require 2RU (rack units) of rack space that will aid in equipment ventilation and cable management.
Overview of the Composite Clock Input/Output Panel
The Syncworks Composite Clock Input/Output (CC I/O) DS1 Expansion Panel is designed to specifically meet our customer’s need to continue supporting legacy synchronization needs in today’s small and large offices, by expanding the number of Composite Clock outputs provided by composite clock sources, e.g. the Microchip TimeProvider® 4100 (TP4100).
The Syncworks’ CC I/O Panel’s unique composite clock input design interfaces with redundant composite clock outputs from the composite clock sources to expand the system’s total number of
available CC outputs to include the 20 CC outputs on the CC I/O Panel.
The DS1 Expansion Panels have redundant power connections, Power A and Power B, to accept -48VDC from the office battery system. The DS1 Expansion Panel has redundant Composite Clock Inputs that are connected to a Timing Signal Generator, e.g. TP4100, connected to Input 1 and a Subtended Timing Signal Generator, e.g. subtended TP4100, connected to Input 2. Once CC inputs are connected, the panel provides 20 CC Outputs to provide synchronized references for legacy equipment that requires CC Inputs. The panel provides alarm indicators/LEDs for each power input, each CC input, and the 20 CC outputs; if any alarm condition is detected the Alarm Relay and Alarm LED will be triggered for remote monitoring of the panel, the alarm will remain active until the source of the alarm condition is resolved.
The Syncworks CC I/O DS1 Expansion Panels come with reversible rack ears that allow it to be mounted in either 19″ or 23″ equipment racks and the panel height will require 2RU (rack units) of rack space that will aid in equipment ventilation and cable management.
About Syncworks
Syncworks is a value-added stocking reseller of network sync and timing equipment for critical infrastructure companies. SyncCare and Field Services ensure your network equipment is flawlessly executed and supported.
Our 10,000 sq. ft. warehouse stocks and ships critical equipment and replacements for networks all across the USA and the Caribbean. With expertise from GPS signal to our new output expansion panels, we an experience and trusted guide. Our tight-knit crew of engineers and field services technicians work together to efficiently and effectively bring your network to Stratum 1 standards.
Syncworks delivers the highest level of expertise to every project and offers a complete menu of network synchronization products and services. Our flagship product, the TimeProvider® 4100, is a gateway clock that accepts multiple inputs from Global Navigation Satellite Systems (GNSS), Synchronous Ethernet (SynE), and 1588 PTP Grandmaster Clock and E1/T1 digital transmission links.
As a Microchip Diamond Partner, we maintain the largest and most diversified stocking supply of Microchip network sync & timing products to meet our customers’ every need when it comes to sync and timing technology.
For more information, contact sales@syncworks.com or call (904) 280-1234.